| Code | 1900846 |
| Name | PROVOR Profiling Float |
| Description | Coriolis - PIRATA 2009 |
| Project |
CORIOLIS
|
| Institution | IRD Brest |
| Data Assembly Center | IF : CORIOLIS |
| Status | |
| First cycle date | 11/07/2009 23:00:00 |
| Last cycle date | 11/06/2013 08:21:14 |
| Float cycles | 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0 |
| Stations | in Ascii, in Netcdf |
| Trajectory data | in Ascii, in Netcdf |
| Graphics of individual profiles | Verticals profiles, Immersion profiles |
| Map | |
| Waterfall profiles | 
 |
| Waterfall profiles (emphasis) | 
 |
| Overlayed profiles | 
 |
| Overlayed profiles (emphasis) | 
 |
| T/S Diagram |  |
| Section chart | 
 |
| Pressure chart |  |
| Battery voltage |  |
| Configuration | | Bathy | 3608 | | Calibration coefficients for this equation | a1=0, a0=0.0000 | | Calibration equation for this parameter | PSAL_ADJUSTED = a1 * PSAL + a0 | | Comment applying to this parameter calibration | Real-time salinity adjustment | | Data centre in charge of platform data processing | IF | | Date (UTC) of the first descent of the float. | 09/07/2009 15:00:00 | | Date of last update of the metadata of the platform | 28/09/2012 19:00:00 | | Date of last update of the trajectory of the platform | 11/06/2013 10:58:28 | | Date of the calibration | 20130328111814 | | Direction of the profiles | B | | Identifier of the deployment platform | ANTEA | | Instrument type | OIN-05-S3-003 | | List of parameters with calibration information | PSAL | | List of parameters with calibration information | PRES | | List of parameters with calibration information | CNDC | | List of parameters with calibration information | TEMP | | List of parameters with real-time calibration information | PSAL | | List of sensors on the float | PRES | | List of sensors on the float | TEMP | | List of sensors on the float | CNDC | | Model of the float | PROVOR CTS3 | | Name of the cruise | PIRATA 2009 | | Name of the network related to the platform | MyOcean | | Name of the network related to the platform | GROUP | | Name of the principal investigator | Yves GOURIOU | | PRES when the SBE pump is switched off | 5 | | Platform activity flag | A | | Positioning system | ARGOS | | Profiler CONDUCTIVITY ACCURACY | 2 | | Profiler CRC TYPE | 16 | | Profiler CYCLE PERIOD | 10 | | Profiler CYCLE PERIOD 1 | 10 | | Profiler CYCLE PERIOD 2 | 10 | | Profiler EXPERIMENT ID | CORIOLIS | | Profiler IMMERSION DRIFT PERIOD | 720 | | Profiler LAUNCH DATETIME | 09/07/2009 15:00:00 | | Profiler LAUNCH LATITUDE | -8.5 | | Profiler LAUNCH LONGITUDE | -10 | | Profiler PARKING DEPTH | 1500 | | Profiler PROBE CODE | 841 | | Profiler PROFILE DEPTH | 2000 | | Profiler RECORDER CODE | 60 | | Profiler REFERENCE DATETIME | 11/07/2009 23:00:00 | | Profiler REFERENCE INTERNAL DATE | 192 | | Profiler TYPE | PROVOR | | Profiler VERSION | 4.22 | | Quality on launch date, time and location | 1 | | Quality on start date | 1 | | The accuracy of the sensor | 0.03 | | The accuracy of the sensor | 0.03 | | The accuracy of the sensor | 3 | | The deepest pressure sampled in the ascending profile | 2000 | | The last valid station id of the platform | 29668404 | | The name of the manufacturer | Seabird | | The name of the manufacturer | Seabird | | The name of the manufacturer | Seabird | | The name of the manufacturer | KANNAD | | The number of times this cycle repeats | 1 | | The pressure of subsurface drifts | 1900 | | The program identifier used by the transmission system | 02412 | | The repetition rate of transmission from the float | 40 | | The resolution of the sensor | 0.001 | | The resolution of the sensor | 0.001 | | The resolution of the sensor | 0.1 | | The telecommunications system used | ARGOS | | The total time of a cycle : descent + parking + ascent + surface | 240 | | The type of battery packs in the float | Lithium | | The units of accuracy and resolution of the sensor | degree_Celsius | | The units of accuracy and resolution of the sensor | Decibar | | The units of accuracy and resolution of the sensor | mS/cm | | Transmission identifier (ARGOS, ORBCOMM, etc.) | 93923 | | Type of sensor | n/a | | Type of sensor | SBE | | Type of sensor | n/a | | Version number of the data handbook | 1.2 |
|
| Missing measures percentages |
chart_missing_measures_ratios
|
| Missing cycles |
chart_missing_cycles
|
| Technical alerts |
chart_tech_alert
|
| Technical parameters |
1900846
28/09/2012 19:00:00
0
|