Description of all floats

Float 1900999

Code1900999
NameSOLO Profiling Float SBE
DescriptionArgo BRAZIL
Project US ARGO PROJECT
InstitutionBRAZIL
Data Assembly CenterAO : AOML
Status
First cycle date16/12/2009 13:05:43
Last cycle date09/05/2013 14:01:18
Float cycles125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 0, 3, 2, 1
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_1900999.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Configuration
Calibration coefficients for this equationa1=0, a0=0.0003
Calibration coefficients for this equationTGAIN=0.001;TOFF=-5.00
Calibration coefficients for this equationSGAIN=0.001;SOFF=-1.00
Calibration coefficients for this equationPOFF=-10; PGAIN=0.1; P1=200; P2=420; P3=2500; DP1=5; DP2=20; DP3=50
Calibration equation for this parameterPSAL_ADJUSTED = a1 * PSAL + a0
Calibration equation for this parameterT = CNTS*TGAIN+TOFF
Calibration equation for this parameterS = CNTS*SGAIN+SOFF
Calibration equation for this parameterP=PGAIN*Pcnt+POFF ; if P_PREV<P1 P=P_PREV+DP1 ; if P1<P_PREV<P2 P=P_PREV+DP2 ; if P2<P_PREV<=P3 P=P_PREV+DP3
Comment applying to this parameter calibrationtemperature calibration date 04 09 2009
Comment applying to this parameter calibrationconductivity calibration date 04 09 2009
Comment applying to this parameter calibrationpressure calibration date 27 08 2009
Comment applying to this parameter calibrationReal-time salinity adjustment
Data centre in charge of platform data processingAO
Date (UTC) of the first descent of the float.06/12/2009 01:34:00
Date of last update of the metadata of the platform24/02/2013 02:13:16
Date of last update of the trajectory of the platform13/05/2013 19:25:28
Date of the calibration20111130072308
Describe any anomalies or problems the float may have had.n/a
Direction of the profilesA
Identifier of stations used to verify the first profilen/a
Identifier of the deployment platformR/V Cruzeiro do Sul
Identifier of the mission used to deploy the floatn/a
Instrument typeSOLO_SBE_0932
List of parameters with calibration informationTEMP
List of parameters with calibration informationPRES
List of parameters with calibration informationPSAL
List of parameters with real-time calibration informationPSAL
List of sensors on the floatCNDC
List of sensors on the floatPRES
List of sensors on the floatTEMP
Model of the floatSOLO_SBE
Name of the network related to the platformMyOcean
Name of the network related to the platformGROUP
Name of the principal investigatorMauricio M. Mata
Platform activity flagA
Positioning systemARGOS
Profiler EXPERIMENT IDUS ARGO PROJECT
Profiler LAUNCH DATETIME06/12/2009 01:44:00
Profiler LAUNCH LATITUDE-20
Profiler LAUNCH LONGITUDE1.973
Profiler PROBE CODE851
Quality on launch date, time and location1
Quality on start date1
The deepest pressure sampled in the ascending profile1800
The last valid station id of the platform29416257
The name of the manufacturerSBE
The name of the manufacturerWHOI
The name of the manufacturerDruck
The name of the manufacturerSBE
The number of times this cycle repeats1
The pressure of subsurface drifts1000
The program identifier used by the transmission system13281
The rate of drift of the float clock0
The related loading id9280217
The repetition rate of transmission from the float60
The serial number of the sensor2085
The serial number of the sensor2958487
The serial number of the sensor2085
The telecommunications system usedARGOS
The time spent at the parking pressure213.6
The time spent at the surface12
The time spent sampling the ascending profile5
The time spent sampling the descending profile8
The total time of a cycle : descent + parking + ascent + surface240
The units of accuracy and resolution of the sensordecibar
The units of accuracy and resolution of the sensormS/cm
The units of accuracy and resolution of the sensordegree_Celsius
Transmission identifier (ARGOS, ORBCOMM, etc.)91955
Type of sensorSBE41CP
Type of sensorn/a
Type of sensorSBE41CP
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 1900999 24/02/2013 02:13:16 0