Float 1901002

Code 1901002
Name SOLO Profiling Float SBE
Description Argo BRAZIL
Project US ARGO PROJECT
Institution BRAZIL
Data Assembly Center AO : AOML
Status
First cycle date 31/12/1949 23:59:59
Last cycle date 18/05/2012 09:01:04
Float cycles 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 0, 13, 50, 49, 48, 47, 46, 45, 51, 10, 11, 12, 9, 8, 7, 6, 5, 4, 3, 1, 2
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_1901002.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Configuration
Calibration coefficients for this equation a1=0, a0=0.0009
Calibration coefficients for this equation TGAIN=0.001;TOFF=-5.00
Calibration coefficients for this equation SGAIN=0.001;SOFF=-1.00
Calibration coefficients for this equation POFF=-10; PGAIN=0.1; P1=700; P2=1200; P3=2500; DP1=2; DP2=5; DP3=10
Calibration equation for this parameter PSAL_ADJUSTED = a1 * PSAL + a0
Calibration equation for this parameter T = CNTS*TGAIN+TOFF
Calibration equation for this parameter S = CNTS*SGAIN+SOFF
Calibration equation for this parameter P=PGAIN*Pcnt+POFF ; if P_PREV<=P1 P=P_PREV+DP1 ; if P1<P_PREV=P2 P=P_PREV+DP2 ; if P2<P_PREV<P3 P=P_PREV+DP3
Comment applying to this parameter calibration temperature calibration date 20 08 2009
Comment applying to this parameter calibration conductivity calibration date 20 08 2009
Comment applying to this parameter calibration pressure calibration date 19 08 2009
Comment applying to this parameter calibration Real-time salinity adjustment
Data centre in charge of platform data processing AO
Date (UTC) of the first descent of the float. 11/12/2009 02:42:00
Date of last update of the metadatas of the platform 09/03/2012 18:16:45
Date of last update of the trajectory of the platform 20/05/2012 21:16:58
Date of the calibration 20120331091753
Describe any anomalies or problems the float may have had. n/a
Direction of the profiles A
Identifier of stations used to verify the first profile n/a
Identifier of the deployment platform R/V Cruzeiro do Sul
Identifier of the mission used to deploy the float n/a
Instrument type SOLOIR_SBE_0944
List of parameters with calibration information TEMP
List of parameters with calibration information PRES
List of parameters with calibration information PSAL
List of parameters with real-time calibration information PSAL
List of sensors on the float CNDC
List of sensors on the float TEMP
List of sensors on the float PRES
Model of the float SOLOIR_SBE
Name of the network related to the platform MyOcean
Name of the network related to the platform GROUP
Name of the network related to the platform GROUP
Name of the principal investigator Mauricio M. Mata
Platform activity flag A
Positioning system GPS
Profiler EXPERIMENT ID US ARGO PROJECT
Profiler LAUNCH DATETIME 11/12/2009 02:52:00
Profiler LAUNCH LATITUDE -20.0005
Profiler LAUNCH LONGITUDE -14.0012
Profiler PROBE CODE 851
Quality on launch date, time and location 1
Quality on start date 1
The deepest pressure sampled in the ascending profile 1800
The last valid station id of the platform 26118495
The name of the manufacturer SBE
The name of the manufacturer WHOI
The name of the manufacturer Druck
The name of the manufacturer SBE
The number of times this cycle repeats 1
The pressure of subsurface drifts 1000
The program identifier used by the transmission system n/a
The rate of drift of the float clock 0
The related loading id 9340023
The repetition rate of transmission from the float -999
The serial number of the sensor 2072989
The serial number of the sensor 2109
The serial number of the sensor 2109
The telecommunications system used IRIDIUM
The time spent at the surface 0.5
The units of accuracy and resolution of the sensor degree_Celsius
The units of accuracy and resolution of the sensor mS/cm
The units of accuracy and resolution of the sensor decibar
Transmission identifier (ARGOS, ORBCOMM, etc.) 300034012035220
Type of sensor n/a
Type of sensor SBE41CP
Type of sensor SBE41CP