| Bathy |
4240 |
| Calibration coefficients for this equation |
None |
| Calibration coefficients for this equation |
None |
| Calibration coefficients for this equation |
None |
| Calibration equation for this parameter |
None |
| Calibration equation for this parameter |
None |
| Calibration equation for this parameter |
None |
| Data centre in charge of platform data processing |
IF |
| Date (UTC) of the first descent of the float. |
17/10/2010 18:26:00 |
| Date of last update of the metadatas of the platform |
18/10/2010 19:00:00 |
| Date of last update of the trajectory of the platform |
25/05/2012 03:01:58 |
| Direction of the profiles |
B |
| Identifier of the deployment platform |
AK Sergey Vavilov |
| Instrument type |
OIN-08-S3-047 |
| List of parameters with calibration information |
TEMP |
| List of parameters with calibration information |
PSAL |
| List of parameters with calibration information |
CNDC |
| List of parameters with calibration information |
PRES |
| List of sensors on the float |
TEMP |
| List of sensors on the float |
CNDC |
| List of sensors on the float |
PRES |
| Model of the float |
PROVOR CTS3 |
| Name of the cruise |
GOODHOPE 2010 |
| Name of the network related to the platform |
GROUP |
| Name of the network related to the platform |
MyOcean |
| Name of the principal investigator |
Sabrina SPEICH et Michel ARHAN |
| Platform activity flag |
A |
| Positioning system |
ARGOS |
| Profiler CONDUCTIVITY ACCURACY |
2 |
| Profiler CRC TYPE |
16 |
| Profiler CYCLE PERIOD |
10 |
| Profiler CYCLE PERIOD 1 |
10 |
| Profiler CYCLE PERIOD 2 |
10 |
| Profiler EXPERIMENT ID |
GOODHOPE |
| Profiler IMMERSION DRIFT PERIOD |
720 |
| Profiler LAUNCH DATETIME |
16/10/2010 05:25:00 |
| Profiler LAUNCH LATITUDE |
-44.987 |
| Profiler LAUNCH LONGITUDE |
6.8 |
| Profiler PARKING DEPTH |
1000 |
| Profiler PROBE CODE |
841 |
| Profiler PROFILE DEPTH |
2000 |
| Profiler RECORDER CODE |
60 |
| Profiler REFERENCE DATETIME |
18/10/2010 20:00:00 |
| Profiler REFERENCE INTERNAL DATE |
291 |
| Profiler TYPE |
PROVOR |
| Profiler VERSION |
4.22 |
| Quality on launch date, time and location |
1 |
| Quality on start date |
1 |
| The accuracy of the sensor |
0.005 |
| The accuracy of the sensor |
0.002 |
| The accuracy of the sensor |
2.4 |
| The deepest pressure sampled in the ascending profile |
2000 |
| The last valid station id of the platform |
26062066 |
| The name of the manufacturer |
Sea-Bird Electronics |
| The name of the manufacturer |
NKE |
| The name of the manufacturer |
Druck |
| The name of the manufacturer |
Sea-Bird Electronics |
| The number of times this cycle repeats |
1 |
| The pressure of subsurface drifts |
1000 |
| The program identifier used by the transmission system |
2412 |
| The repetition rate of transmission from the float |
40 |
| The resolution of the sensor |
0.001 |
| The resolution of the sensor |
0.001 |
| The resolution of the sensor |
0.1 |
| The serial number of the sensor |
None |
| The serial number of the sensor |
None |
| The serial number of the sensor |
None |
| The telecommunications system used |
ARGOS |
| The total time of a cycle : descent + parking + ascent + surface |
240 |
| The units of accuracy and resolution of the sensor |
mS.cm-1 |
| The units of accuracy and resolution of the sensor |
Dbar |
| The units of accuracy and resolution of the sensor |
Degree Celsius |
| Transmission identifier (ARGOS, ORBCOMM, etc.) |
88393 |
| Type of sensor |
SBE41CP |
| Type of sensor |
SBE41CP |
| Type of sensor |
SBE41CP ¿ 2900 PSIA |
| Version number of the data handbook |
1.2 |