| Antenna Serial Number | 33036-34377-36 |
| Bathy | 3534 |
| Battery Serial Number | 1019-38 |
| Battery Serial Number | 1019-37 |
| Blue Tooth Serial Number | 2010-06-19 |
| CPU Serial Number | I535-108412-19 |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Data centre in charge of platform data processing | IF |
| Date (UTC) of the first descent of the float. | 29/07/2011 02:33:10 |
| Date of last update of the metadata of the platform | 04/10/2012 19:00:00 |
| Date of last update of the trajectory of the platform | 18/05/2013 02:11:58 |
| Direction of the profiles | B |
| Doxy CPU Serial Number | I538-14 |
| Firmware version | 5817A00 |
| Hydraulic Pump Serial Number | 459 |
| Identifier of the deployment platform | DBBH |
| Instrument type | OIN-10-S3-DO-014 |
| Internal Vacuum Equation | A*COUNTS + B |
| Internal Vacuum coefficients for the equation | A=1.551; B=237.50 |
| List of parameters with calibration information | TEMP |
| List of parameters with calibration information | DOXY |
| List of parameters with calibration information | PRES |
| List of parameters with calibration information | PSAL |
| List of parameters with calibration information | CNDC |
| List of sensors on the float | CNDC |
| List of sensors on the float | DOXY |
| List of sensors on the float | PRES |
| List of sensors on the float | TEMP |
| Model of the float | PROVOR CTS3-DO |
| Name of the cruise | M85/1 |
| Name of the network related to the platform | MyOcean |
| Name of the network related to the platform | GROUP |
| Name of the principal investigator | Virginie THIERRY |
| PRES when the SBE pump is switched off | 5 |
| Platform activity flag | A |
| Positioning system | ARGOS |
| Pressure Case Serial Number | 5260 |
| Profiler CONDUCTIVITY ACCURACY | 2 |
| Profiler CRC TYPE | 16 |
| Profiler CYCLE PERIOD | 10 |
| Profiler CYCLE PERIOD 1 | 10 |
| Profiler CYCLE PERIOD 2 | 10 |
| Profiler EXPERIMENT ID | CORIOLIS_OVIDE |
| Profiler IMMERSION DRIFT PERIOD | 720 |
| Profiler LAUNCH DATETIME | 29/07/2011 04:45:25 |
| Profiler LAUNCH LATITUDE | 56.293 |
| Profiler LAUNCH LONGITUDE | -52.407 |
| Profiler PARKING DEPTH | 1000 |
| Profiler PROBE CODE | 841 |
| Profiler PROFILE DEPTH | 2000 |
| Profiler RECORDER CODE | 60 |
| Profiler REFERENCE DATETIME | 30/07/2011 23:00:00 |
| Profiler REFERENCE INTERNAL DATE | 211 |
| Profiler TYPE | PROVOR |
| Profiler VERSION | 4.41 |
| Quality on launch date, time and location | 1 |
| Quality on start date | 1 |
| The accuracy of the sensor | 8 |
| The accuracy of the sensor | 2.4 |
| The accuracy of the sensor | 0.005 |
| The accuracy of the sensor | 0.002 |
| The deepest pressure sampled in the ascending profile | 2000 |
| The last valid station id of the platform | 29420137 |
| The name of the manufacturer | Druck |
| The name of the manufacturer | Sea-Bird Electronics |
| The name of the manufacturer | Sea-Bird Electronics |
| The name of the manufacturer | NKE |
| The name of the manufacturer | Aandera |
| The number of times this cycle repeats | 1 |
| The pressure of subsurface drifts | 1000 |
| The program identifier used by the transmission system | 2412 |
| The repetition rate of transmission from the float | 40 |
| The resolution of the sensor | 1 |
| The resolution of the sensor | 0.1 |
| The resolution of the sensor | 0.001 |
| The resolution of the sensor | 0.001 |
| The serial number of the sensor | 322 |
| The serial number of the sensor | 3234 |
| The serial number of the sensor | 3234 |
| The serial number of the sensor | 3234 |
| The telecommunications system used | ARGOS |
| The total time of a cycle : descent + parking + ascent + surface | 240 |
| The type of battery packs in the float | Lithium |
| The units of accuracy and resolution of the sensor | Dbar |
| The units of accuracy and resolution of the sensor | Degree Celsius |
| The units of accuracy and resolution of the sensor | mS.cm-1 |
| The units of accuracy and resolution of the sensor | u M/l |
| Transmission identifier (ARGOS, ORBCOMM, etc.) | 75225 |
| Type of sensor | SBE41CP ¿ 2900 PSIA |
| Type of sensor | Optode 4330 |
| Type of sensor | SBE41CP |
| Type of sensor | SBE41CP |
| Version number of the data handbook | 1.2 |