Description of all floats

Float 1901460

Code1901460
NameSOLO Profiling Float SBE_0925
DescriptionArgo WHOI
Project US ARGO PROJECT
InstitutionUNIVERSITY OF WASHINGTON (SEATTLE)
Data Assembly CenterAO : AOML
Status
First cycle date15/05/2010 05:57:38
Last cycle date18/05/2013 10:29:59
Float cycles110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_1901460.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Configuration
Calibration coefficients for this equationa1=0, a0=0.0009
Calibration coefficients for this equationTGAIN=0.001;TOFF=-5.00
Calibration coefficients for this equationSGAIN=0.001;SOFF=-1.00
Calibration coefficients for this equationPOFF=-10; PGAIN=0.1; P1=200; P2=410; P3=2500; DP1=5; DP2=20; DP3=50
Calibration equation for this parameterPSAL_ADJUSTED = a1 * PSAL + a0
Calibration equation for this parameterT = CNTS*TGAIN+TOFF
Calibration equation for this parameterS = CNTS*SGAIN+SOFF
Calibration equation for this parameterP=PGAIN*Pcnt+POFF ; if P_PREV<=P1 P=P_PREV+DP1 ; if P1<P_PREV<P2 P=P_PREV+DP2 ; if P2<P_PREV<=P3 P=P_PREV+DP3
Comment applying to this parameter calibrationtemperature calibration date 30 10 2009
Comment applying to this parameter calibrationconductivity calibration date 30 10 2009
Comment applying to this parameter calibrationpressure calibration date 07 10 2009
Comment applying to this parameter calibrationReal-time salinity adjustment
Data centre in charge of platform data processingAO
Date (UTC) of the first descent of the float.09/05/2010 21:20:00
Date of last update of the metadata of the platform24/02/2013 02:13:56
Date of last update of the trajectory of the platform19/05/2013 19:16:40
Date of the calibration20111222064603
Describe any anomalies or problems the float may have had.n/a
Direction of the profilesA
Identifier of stations used to verify the first profileyes
Identifier of the deployment platformR/V Ron Brown
Identifier of the mission used to deploy the floatPNE 2010 (RB-10-03)
Instrument typeSOLO_SBE_0925
List of parameters with calibration informationTEMP
List of parameters with calibration informationPRES
List of parameters with calibration informationPSAL
List of parameters with real-time calibration informationPSAL
List of sensors on the floatCNDC
List of sensors on the floatPRES
List of sensors on the floatTEMP
Model of the floatSOLO_SBE
Name of the network related to the platformMyOcean
Name of the network related to the platformGROUP
Name of the principal investigatorBreck Owens
Platform activity flagA
Positioning systemARGOS
Profiler EXPERIMENT IDUS ARGO PROJECT
Profiler LAUNCH DATETIME14/05/2010 17:48:00
Profiler LAUNCH LATITUDE20.0265
Profiler LAUNCH LONGITUDE-37.8857
Profiler PROBE CODE851
Quality on launch date, time and location1
Quality on start date1
The deepest pressure sampled in the ascending profile1800
The last valid station id of the platform29477757
The name of the manufacturerSBE
The name of the manufacturerWHOI
The name of the manufacturerDruck
The name of the manufacturerSBE
The number of times this cycle repeats1
The pressure of subsurface drifts1000
The program identifier used by the transmission system13281
The rate of drift of the float clock0
The related loading id9280230
The repetition rate of transmission from the float60
The serial number of the sensor2088
The serial number of the sensor2832887
The serial number of the sensor2088
The telecommunications system usedARGOS
The time spent at the parking pressure216
The time spent at the surface12
The time spent sampling the ascending profile3
The time spent sampling the descending profile8
The total time of a cycle : descent + parking + ascent + surface240
The units of accuracy and resolution of the sensordecibar
The units of accuracy and resolution of the sensormS/cm
The units of accuracy and resolution of the sensordegree_Celsius
Transmission identifier (ARGOS, ORBCOMM, etc.)84848
Type of sensorSBE41CP
Type of sensorn/a
Type of sensorSBE41CP
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 1901460 24/02/2013 02:13:56 0