| Calibration coefficients for this equation |
a1=0, a0=0.0001 |
| Calibration coefficients for this equation |
a0=-4.071986e-05 a1=2.792762e-04 a2=-2.783991e-06 a3=1.598800e-07 |
| Calibration coefficients for this equation |
PA0=6.839217e+00 PA1=1.400352e-01 PA2=-3.830331e-08 PTCA0=-6.278421e+00 PTCA1=2.275354e+00 PTCA2=-8.389975e-03 PTCB0=2.559638e+01 PTCB1=1.675000e-03 PTCB2=0.000000e+00 PTHA0=-6.399327e+01 PTHA1=4.925762e-02 PTHA2=3.201279e-07 |
| Calibration coefficients for this equation |
g=-9.905965e-01 h=1.518189e-01 i=-4.067310e-04 j=5.447239e-05 CPCOR=-9.570000e-08 CTCOR=3.250000e-06 WBOTC=-4.230948e-07 |
| Calibration equation for this parameter |
PSAL_ADJUSTED = a1 * PSAL + a0 |
| Calibration equation for this parameter |
Conductivity(S/m)=(g+h*f^2+i*f^3+j*f^4)/(1+CTcor*t+CPcor*p) where f=output*sqrt(1.0+WBOTC*t)/1000, t=TEMP, p=PRES |
| Calibration equation for this parameter |
Temperature[ITS-90](degC)=1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 where n=output |
| Calibration equation for this parameter |
Pressure(psia)=PA0+PA1*n+PA2*n^2 where n=(output-PTCA0+PTCA1*t+PTCA2*t^2)*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2), t=PTHA0+PTHA1*y+PTHA2*y^2, y=thermistor_output |
| Comment applying to this parameter calibration |
Real-time salinity adjustment |
| Comment applying to this parameter calibration |
calibrated at 2007/08/02 |
| Comment applying to this parameter calibration |
calibrated at 2007/07/16 |
| Comment applying to this parameter calibration |
calibrated at 2007/08/02 |
| Data centre in charge of platform data processing |
JA |
| Date (UTC) of the first descent of the float. |
08/12/2008 02:05:29 |
| Date of last update of the metadatas of the platform |
19/05/2009 11:43:08 |
| Date of last update of the trajectory of the platform |
17/05/2012 16:14:07 |
| Date of the calibration |
20110827222043 |
| Direction of the profiles |
A |
| Identifier of the deployment platform |
Koyomaru |
| Identifier of the mission used to deploy the float |
010 |
| Instrument type |
APEX-SBE 3539 |
| List of parameters with calibration information |
CNDC |
| List of parameters with calibration information |
PRES |
| List of parameters with calibration information |
TEMP |
| List of parameters with real-time calibration information |
PSAL |
| List of sensors on the float |
PRES |
| List of sensors on the float |
PSAL |
| List of sensors on the float |
TEMP |
| Model of the float |
APEX-SBE |
| Name of the network related to the platform |
GROUP |
| Name of the principal investigator |
JAMSTEC |
| Platform activity flag |
A |
| Positioning system |
ARGOS |
| Profiler EXPERIMENT ID |
J-ARGO |
| Profiler LAUNCH DATETIME |
08/12/2008 03:28:00 |
| Profiler LAUNCH LATITUDE |
1.094 |
| Profiler LAUNCH LONGITUDE |
90.091 |
| Profiler PROBE CODE |
846 |
| Quality on launch date, time and location |
1 |
| Quality on start date |
1 |
| The accuracy of the sensor |
0.005 |
| The accuracy of the sensor |
2.4 |
| The accuracy of the sensor |
0.002 |
| The deepest pressure sampled in the ascending profile |
1525 |
| The frequency of transmission from the float |
401655450 |
| The last valid station id of the platform |
26139382 |
| The name of the manufacturer |
SEA-BIRD ELECTRONICS, INC. |
| The name of the manufacturer |
SEA-BIRD ELECTRONICS, INC. (Druck) |
| The name of the manufacturer |
Webb Research Corporation |
| The name of the manufacturer |
SEA-BIRD ELECTRONICS, INC. |
| The number of times this cycle repeats |
1 |
| The pressure of subsurface drifts |
1000 |
| The program identifier used by the transmission system |
02147 |
| The repetition rate of transmission from the float |
30 |
| The resolution of the sensor |
0.001 |
| The resolution of the sensor |
0.001 |
| The resolution of the sensor |
0.1 |
| The serial number of the sensor |
3575 (2465251) |
| The serial number of the sensor |
3575 |
| The serial number of the sensor |
3575 |
| The telecommunications system used |
ARGOS |
| The time spent at the parking pressure |
218.73 |
| The time spent at the surface |
12.29 |
| The time spent sampling the ascending profile |
4.71 |
| The time spent sampling the descending profile |
4.27 |
| The total time of a cycle : descent + parking + ascent + surface |
240 |
| The units of accuracy and resolution of the sensor |
psu |
| The units of accuracy and resolution of the sensor |
degC |
| The units of accuracy and resolution of the sensor |
dbar |
| Transmission identifier (ARGOS, ORBCOMM, etc.) |
76294 |
| Type of sensor |
SBE41 |
| Type of sensor |
SBE41 |
| Type of sensor |
SBE41 |