Description of all floats

Float 3900652

Code 3900652
Name SOLO Profiling Float
Description Argo BRAZIL
Project US ARGO PROJECT
Institution BRAZIL
Data Assembly Center AO : AOML
Status
First cycle date 31/12/1949 23:59:59
Last cycle date 23/05/2012 04:00:34
Float cycles 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 149, 148, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 73, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 14, 9, 5, 4, 3, 0, 147, 150, 7, 8, 10, 11, 12, 13, 15, 16, 17, 18, 19, 44, 45, 46, 47, 48, 49, 71, 72, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 113, 114, 115, 6, 1, 2
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_3900652.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Configuration
Calibration coefficients for this equation SGAIN=0.001;SOFF=-1.00
Calibration coefficients for this equation POFF=-10; PGAIN=0.1; P1=200; P2=400; P3=2000; DP1=5; DP2=20; DP3=50
Calibration coefficients for this equation TGAIN=0.001;TOFF=-5.00
Calibration equation for this parameter S = CNTS*SGAIN+SOFF
Calibration equation for this parameter T = CNTS*TGAIN+TOFF
Calibration equation for this parameter P=PGAIN*Pcnt+POFF ; if P_PREV<P1 P=P_PREV+DP1 ; if P1<=P_PREV<P2 P=P_PREV+DP2 ; if P2<P_PREV<=P3 P=P_PREV+DP3
Comment applying to this parameter calibration temperature calibration date n/a
Comment applying to this parameter calibration pressure calibration date n/a
Comment applying to this parameter calibration conductivity calibration date n/a
Data centre in charge of platform data processing AO
Date (UTC) of the first descent of the float. 14/12/2007 21:20:00
Date of last update of the metadatas of the platform 25/11/2011 06:41:41
Date of last update of the trajectory of the platform 24/05/2012 03:25:57
Describe any anomalies or problems the float may have had. n/a
Direction of the profiles A
Identifier of stations used to verify the first profile n/a
Identifier of the deployment platform VOS unknown
Identifier of the mission used to deploy the float MOVAR
Instrument type SOLO_SBE_SL686
List of parameters with calibration information PRES
List of parameters with calibration information TEMP
List of parameters with calibration information PSAL
List of sensors on the float TEMP
List of sensors on the float CNDC
List of sensors on the float PRES
Model of the float SOLO_SBE
Name of the network related to the platform MyOcean
Name of the network related to the platform GROUP
Name of the network related to the platform GROUP
Name of the principal investigator Mauricio M. Mata
Platform activity flag A
Positioning system ARGOS
Profiler EXPERIMENT ID US ARGO PROJECT
Profiler LAUNCH DATETIME 14/12/2007 21:30:00
Profiler LAUNCH LATITUDE -21.0533
Profiler LAUNCH LONGITUDE -33.7867
Profiler PROBE CODE 851
Quality on launch date, time and location 1
Quality on start date 1
The deepest pressure sampled in the ascending profile 1800
The last valid station id of the platform 26011523
The name of the manufacturer SBE
The name of the manufacturer SBE
The name of the manufacturer WHOI
The name of the manufacturer Druck
The number of times this cycle repeats 1
The pressure of subsurface drifts 1000
The program identifier used by the transmission system 13281
The rate of drift of the float clock 0
The related loading id 9280279
The repetition rate of transmission from the float 60
The serial number of the sensor 10521
The serial number of the sensor 1414
The serial number of the sensor 1414
The telecommunications system used ARGOS
The time spent at the parking pressure 196.999
The time spent at the surface 12
The time spent sampling the ascending profile 21
The time spent sampling the descending profile 21
The total time of a cycle : descent + parking + ascent + surface 240
The units of accuracy and resolution of the sensor mS/cm
The units of accuracy and resolution of the sensor decibar
The units of accuracy and resolution of the sensor degree_Celsius
Transmission identifier (ARGOS, ORBCOMM, etc.) 67435
Type of sensor n/a
Type of sensor SBE41CP
Type of sensor SBE41CP