Description of all floats

Float 3900751

Code 3900751
Name SOLO Profiling Float
Description Argo BRAZIL
Project US ARGO PROJECT
Institution BRAZIL
Data Assembly Center AO : AOML
Status
First cycle date 30/06/2009 01:23:42
Last cycle date 14/05/2012 10:47:03
Float cycles 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 0, 1
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_3900751.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Configuration
Calibration coefficients for this equation a1=0, a0=0.0010
Calibration coefficients for this equation TGAIN=0.001;TOFF=-5.00
Calibration coefficients for this equation SGAIN=0.001;SOFF=-1.00
Calibration coefficients for this equation POFF=-10; PGAIN=0.1; P1=200; P2=420; P3=2000; DP1=5; DP2=20; DP3=50
Calibration equation for this parameter PSAL_ADJUSTED = a1 * PSAL + a0
Calibration equation for this parameter T = CNTS*TGAIN+TOFF
Calibration equation for this parameter S = CNTS*SGAIN+SOFF
Calibration equation for this parameter P=PGAIN*Pcnt+POFF ; if P_PREV<P1 P=P_PREV+DP1 ; if P1<=P_PREV<P2 P=P_PREV+DP2 ; if P2<P_PREV<=P3 P=P_PREV+DP3
Comment applying to this parameter calibration temperature calibration date 11 01 2008
Comment applying to this parameter calibration conductivity calibration date 31 01 2008
Comment applying to this parameter calibration pressure calibration date 09 01 2008
Comment applying to this parameter calibration Real-time salinity adjustment
Data centre in charge of platform data processing AO
Date (UTC) of the first descent of the float. 20/06/2009 12:10:00
Date of last update of the metadatas of the platform 09/03/2012 18:16:52
Date of last update of the trajectory of the platform 16/05/2012 14:26:33
Date of the calibration 20120420084951
Describe any anomalies or problems the float may have had. n/a
Direction of the profiles A
Identifier of stations used to verify the first profile XBT
Identifier of the deployment platform R/V NPo Maximiano
Identifier of the mission used to deploy the float AX97
Instrument type SOLO_SBE_SL848
List of parameters with calibration information TEMP
List of parameters with calibration information PRES
List of parameters with calibration information PSAL
List of parameters with real-time calibration information PSAL
List of sensors on the float CNDC
List of sensors on the float TEMP
List of sensors on the float PRES
Model of the float SOLO_SBE
Name of the network related to the platform MyOcean
Name of the network related to the platform GROUP
Name of the network related to the platform GROUP
Name of the principal investigator Mauricio M. Mata
Platform activity flag A
Positioning system ARGOS
Profiler EXPERIMENT ID US ARGO PROJECT
Profiler LAUNCH DATETIME 29/06/2009 12:50:00
Profiler LAUNCH LATITUDE -23.5017
Profiler LAUNCH LONGITUDE -32.01
Profiler PROBE CODE 851
Quality on launch date, time and location 1
Quality on start date 1
The deepest pressure sampled in the ascending profile 1800
The last valid station id of the platform 26094162
The name of the manufacturer SBE
The name of the manufacturer WHOI
The name of the manufacturer Druck
The name of the manufacturer SBE
The number of times this cycle repeats 1
The pressure of subsurface drifts 1000
The program identifier used by the transmission system 13281
The rate of drift of the float clock 0
The related loading id 9280312
The repetition rate of transmission from the float 60
The serial number of the sensor 2043
The serial number of the sensor 2606480
The serial number of the sensor 2043
The telecommunications system used ARGOS
The time spent at the parking pressure 196.999
The time spent at the surface 12
The time spent sampling the ascending profile 21.25
The time spent sampling the descending profile 21.25
The total time of a cycle : descent + parking + ascent + surface 240
The units of accuracy and resolution of the sensor decibar
The units of accuracy and resolution of the sensor mS/cm
The units of accuracy and resolution of the sensor degree_Celsius
Transmission identifier (ARGOS, ORBCOMM, etc.) 80385
Type of sensor SBE41CP
Type of sensor n/a
Type of sensor SBE41CP