| Calibration coefficients for this equation |
a0=3.804939e-05 a1=2.689542e-04 a2=-2.080995e-06 a3=1.400569e-07 |
| Calibration coefficients for this equation |
PA0=3.828484e-01 PA1=1.370119e-01 PA2=1.373537e-08 PTCA0=-1.586459e+02 PTCA1=-3.388478e-01 PTCA2=2.068823e-02 PTCB0=1.035553e+02 PTCB1=-2.000000e-03 PTCB2=0.000000e+00 PTHA0=-9.152610e+01 PTHA1=3.896777e-02 PTHA2=1.062783e-06 |
| Calibration coefficients for this equation |
g=-1.043397e+00 h=1.572337e-01 i=-3.908684e-04 j=5.196508e-05 CPcor=-9.570001e-08 CTcor=3.250000e-06 WBOTC=0.000000e+00 |
| Calibration equation for this parameter |
Conductivity(S/m)=(g+h*f^2+i*f^3+j*f^4)/(1+CTcor*t+CPcor*p) where f=output*sqrt(1.0+WBOTC*t)/1000, t=TEMP, p=PRES |
| Calibration equation for this parameter |
Temperature[ITS-90](degC)=1/{a0+a1[ln(n)]+a2[ln^2(n)]+a3[ln^3(n)]}-273.15 where n=output |
| Calibration equation for this parameter |
Pressure(psia)=PA0+PA1*n+PA2*n^2 where n=(output-PTCA0+PTCA1*t+PTCA2*t^2)*PTCB0/(PTCB0+PTCB1*t+PTCB2*t^2), t=PTHA0+PTHA1*y+PTHA2*y^2, y=thermistor_output |
| Comment applying to this parameter calibration |
calibrated at 2010/05/19 |
| Comment applying to this parameter calibration |
calibrated at 2010/09/02 |
| Comment applying to this parameter calibration |
calibrated at 2010/09/02 |
| Data centre in charge of platform data processing |
JA |
| Date (UTC) of the first descent of the float. |
18/11/2011 02:20:06 |
| Date of last update of the metadatas of the platform |
27/11/2011 06:30:37 |
| Date of last update of the trajectory of the platform |
23/05/2012 07:58:59 |
| Direction of the profiles |
A |
| Identifier of the deployment platform |
NYK_TERRA |
| Identifier of the mission used to deploy the float |
201111 |
| Instrument type |
APEX-SBE 5219 |
| List of parameters with calibration information |
PRES |
| List of parameters with calibration information |
TEMP |
| List of parameters with calibration information |
CNDC |
| List of sensors on the float |
PSAL |
| List of sensors on the float |
PRES |
| List of sensors on the float |
TEMP |
| Model of the float |
APEX-SBE |
| Name of the network related to the platform |
MyOcean |
| Name of the network related to the platform |
GROUP |
| Name of the principal investigator |
JAMSTEC |
| Platform activity flag |
A |
| Positioning system |
ARGOS |
| Profiler EXPERIMENT ID |
J-ARGO |
| Profiler LAUNCH DATETIME |
17/11/2011 19:10:00 |
| Profiler LAUNCH LATITUDE |
46.47 |
| Profiler LAUNCH LONGITUDE |
-172.218 |
| Profiler PROBE CODE |
846 |
| Quality on launch date, time and location |
1 |
| Quality on start date |
1 |
| The accuracy of the sensor |
2.4 |
| The accuracy of the sensor |
0.005 |
| The accuracy of the sensor |
0.002 |
| The deepest pressure sampled in the ascending profile |
2000 |
| The frequency of transmission from the float |
401652000 |
| The last valid station id of the platform |
26115752 |
| The name of the manufacturer |
Webb Research Corporation |
| The name of the manufacturer |
SEA-BIRD ELECTRONICS, INC. _ Kistler |
| The name of the manufacturer |
SEA-BIRD ELECTRONICS, INC. |
| The name of the manufacturer |
SEA-BIRD ELECTRONICS, INC. |
| The number of times this cycle repeats |
1 |
| The pressure of subsurface drifts |
1000 |
| The program identifier used by the transmission system |
02147 |
| The related loading id |
9363050 |
| The repetition rate of transmission from the float |
30 |
| The resolution of the sensor |
0.001 |
| The resolution of the sensor |
0.001 |
| The resolution of the sensor |
0.1 |
| The serial number of the sensor |
4994 _ 2077463 |
| The serial number of the sensor |
4994 |
| The serial number of the sensor |
4994 |
| The telecommunications system used |
ARGOS |
| The time spent at the parking pressure |
215 |
| The time spent at the surface |
9 |
| The time spent sampling the ascending profile |
6 |
| The time spent sampling the descending profile |
10 |
| The total time of a cycle : descent + parking + ascent + surface |
240 |
| The units of accuracy and resolution of the sensor |
psu |
| The units of accuracy and resolution of the sensor |
degC |
| The units of accuracy and resolution of the sensor |
dbar |
| Transmission identifier (ARGOS, ORBCOMM, etc.) |
70406 |
| Type of sensor |
SBE41 |
| Type of sensor |
SBE41 |
| Type of sensor |
SBE41 |