Description of all floats

Float 4901225

Code4901225
NameSOLO Profiling Float IR_SBE_0975
DescriptionArgo WHOI
Project US ARGO PROJECT
InstitutionWOODS HOLE OCEANOGRAPHIC INSTITUTION
Data Assembly CenterAO : AOML
Status
First cycle date18/04/2011 09:21:00
Last cycle date16/06/2013 07:54:46
Float cycles81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 61, 62, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 0, 1
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_4901225.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Configuration
Calibration coefficients for this equationa1=0, a0=0.0006
Calibration coefficients for this equationTGAIN=0.001;TOFF=-5.00
Calibration coefficients for this equationSGAIN=0.001;SOFF=-1.00
Calibration coefficients for this equationPOFF=-10; PGAIN=0.1; P1=700; P2=1200; P3=2500; DP1=2; DP2=5; DP3=10
Calibration equation for this parameterPSAL_ADJUSTED = a1 * PSAL + a0
Calibration equation for this parameterT = CNTS*TGAIN+TOFF
Calibration equation for this parameterS = CNTS*SGAIN+SOFF
Calibration equation for this parameterP=PGAIN*Pcnt+POFF ; if P_PREV<=P1 P=P_PREV+DP1 ; if P1<P_PREV<P2 P=P_PREV+DP2 ; if P2<=P_PREV<=P3 P=P_PREV+DP3
Comment applying to this parameter calibrationtemperature calibration date 25 03 2010
Comment applying to this parameter calibrationconductivity calibration date 25 03 2010
Comment applying to this parameter calibrationpressure calibration date 24 02 2010
Comment applying to this parameter calibrationReal-time salinity adjustment
Data centre in charge of platform data processingAO
Date (UTC) of the first descent of the float.26/03/2011 11:44:00
Date of last update of the metadata of the platform24/02/2013 02:16:45
Date of last update of the trajectory of the platform17/06/2013 03:59:51
Date of the calibration20120331081921
Describe any anomalies or problems the float may have had.n/a
Direction of the profilesA
Identifier of stations used to verify the first profilen/a
Identifier of the deployment platformVOS M/V Maersk Vilnius
Identifier of the mission used to deploy the floatAX08
Instrument typeSOLOIR_SBE_0975
List of parameters with calibration informationTEMP
List of parameters with calibration informationPRES
List of parameters with calibration informationPSAL
List of parameters with real-time calibration informationPSAL
List of sensors on the floatCNDC
List of sensors on the floatPRES
List of sensors on the floatTEMP
Model of the floatSOLOIR_SBE
Name of the network related to the platformMyOcean
Name of the network related to the platformGROUP
Name of the principal investigatorBreck Owens
Platform activity flagA
Positioning systemGPS
Profiler EXPERIMENT IDUS ARGO PROJECT
Profiler LAUNCH DATETIME29/03/2011 18:00:00
Profiler LAUNCH LATITUDE-16.9895
Profiler LAUNCH LONGITUDE-2.67033
Profiler PROBE CODE851
Quality on launch date, time and location1
Quality on start date1
The deepest pressure sampled in the ascending profile1800
The last valid station id of the platform29642853
The name of the manufacturerSBE
The name of the manufacturerWHOI
The name of the manufacturerDruck
The name of the manufacturerSBE
The number of times this cycle repeats1
The pressure of subsurface drifts1000
The program identifier used by the transmission systemn/a
The rate of drift of the float clock0
The related loading id9333051
The repetition rate of transmission from the float-999
The serial number of the sensor2093
The serial number of the sensor2093
The serial number of the sensor2606391
The telecommunications system usedIRIDIUM
The time spent at the surface0.5
The units of accuracy and resolution of the sensordegree_Celsius
The units of accuracy and resolution of the sensormS/cm
The units of accuracy and resolution of the sensordecibar
Transmission identifier (ARGOS, ORBCOMM, etc.)25730
Type of sensorn/a
Type of sensorSBE41CP
Type of sensorSBE41CP
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 4901225 24/02/2013 02:16:45 0