Description of all floats

Float 5902269

Code5902269
NamePROVOR Profiling Float
DescriptionCoriolis-Ovide
Project OVIDE
InstitutionIFREMER
Data Assembly CenterIF : CORIOLIS
Status
First cycle date29/06/2010 23:00:00
Last cycle date25/05/2013 08:32:03
Float cycles106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_5902269.png
Click here to access the interactive map
Waterfall profiles

Waterfall profiles (emphasis)

Overlayed profiles

Overlayed profiles (emphasis)

T/S Diagram
Section chart

Pressure chart
Battery voltage
Configuration
Bathy2986
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Data centre in charge of platform data processingIF
Date (UTC) of the first descent of the float.28/06/2010 15:46:00
Date of last update of the metadata of the platform03/10/2012 19:00:00
Date of last update of the trajectory of the platform25/05/2013 10:58:26
Direction of the profilesB
Firmware version9,03
Identifier of the deployment platformTHALASSA
Instrument typeOIN-08-S3-DO-001
List of parameters with calibration informationTEMP
List of parameters with calibration informationDOXY
List of parameters with calibration informationPRES
List of parameters with calibration informationPSAL
List of parameters with calibration informationCNDC
List of sensors on the floatCNDC
List of sensors on the floatDOXY
List of sensors on the floatPRES
List of sensors on the floatTEMP
Model of the floatPROVOR CTS3-DO 9
Name of the cruiseOVIDE
Name of the network related to the platformMyOcean
Name of the network related to the platformGROUP
Name of the principal investigatorVirginie THIERRY
PRES when the SBE pump is switched off5
Platform activity flagA
Positioning systemARGOS
Profiler CONDUCTIVITY ACCURACY2
Profiler CRC TYPE16
Profiler CYCLE PERIOD10
Profiler CYCLE PERIOD 110
Profiler CYCLE PERIOD 210
Profiler EXPERIMENT IDOVIDE
Profiler IMMERSION DRIFT PERIOD720
Profiler LAUNCH DATETIME28/06/2010 15:49:00
Profiler LAUNCH LATITUDE59.62625
Profiler LAUNCH LONGITUDE-38.9345
Profiler PARKING DEPTH1000
Profiler PROBE CODE841
Profiler PROFILE DEPTH2000
Profiler RECORDER CODE60
Profiler REFERENCE DATETIME29/06/2010 23:00:00
Profiler REFERENCE INTERNAL DATE180
Profiler TYPEPROVOR
Profiler VERSION4.41
Quality on launch date, time and location1
Quality on start date1
The accuracy of the sensor0.002
The accuracy of the sensor0.005
The accuracy of the sensor8
The accuracy of the sensor2.4
The deepest pressure sampled in the ascending profile2000
The last valid station id of the platform29458333
The name of the manufacturerAanderaa
The name of the manufacturerSea-Bird Electronics
The name of the manufacturerSea-Bird Electronics
The name of the manufacturerNKE
The name of the manufacturerDruck
The number of times this cycle repeats1
The pressure of subsurface drifts1000
The program identifier used by the transmission system02412
The repetition rate of transmission from the float45
The resolution of the sensor0.001
The resolution of the sensor0.1
The resolution of the sensor1
The resolution of the sensor0.001
The serial number of the sensorNone
The serial number of the sensorNone
The serial number of the sensorNone
The serial number of the sensorNone
The telecommunications system usedARGOS
The total time of a cycle : descent + parking + ascent + surface240
The type of battery packs in the floatLithium
The units of accuracy and resolution of the sensorDbar
The units of accuracy and resolution of the sensorDegree Celsius
The units of accuracy and resolution of the sensormS.cm-1
The units of accuracy and resolution of the sensorµM/L
Transmission identifier (ARGOS, ORBCOMM, etc.)88428
Type of sensorSBE41CP
Type of sensorSBE41CP
Type of sensorSBE41CP ¿ 2900 PSIA
Type of sensorOptode 3830
Version number of the data handbook1.2
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 5902269 03/10/2012 19:00:00 0