Description of all floats

Float 5902307

Code 5902307
Name PROVOR Profiling Float
Description Coriolis-Ovide
Project OVIDE
Institution IFREMER
Data Assembly Center IF : CORIOLIS
Status
First cycle date 18/06/2010 23:00:00
Last cycle date 19/05/2012 15:33:43
Float cycles 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_5902307.png
Click here to access the interactive map
Waterfall profiles

Waterfall profiles (emphasis)

Overlayed profiles

Overlayed profiles (emphasis)

T/S Diagram
Section chart

Pressure chart
Battery voltage
Configuration
Bathy 4508
Calibration coefficients for this equation None
Calibration coefficients for this equation None
Calibration coefficients for this equation None
Calibration coefficients for this equation None
Calibration equation for this parameter None
Calibration equation for this parameter None
Calibration equation for this parameter None
Calibration equation for this parameter None
Data centre in charge of platform data processing IF
Date (UTC) of the first descent of the float. 17/06/2010 15:46:00
Date of last update of the metadatas of the platform 21/06/2010 19:00:00
Date of last update of the trajectory of the platform 24/05/2012 11:38:05
Direction of the profiles B
Identifier of the deployment platform THALASSA
Instrument type OIN-09-DO-S3-014
List of parameters with calibration information TEMP
List of parameters with calibration information DOXY
List of parameters with calibration information PRES
List of parameters with calibration information PSAL
List of parameters with calibration information CNDC
List of sensors on the float CNDC
List of sensors on the float DOXY
List of sensors on the float PRES
List of sensors on the float TEMP
Model of the float PROVOR CTS3 DO 9.05
Name of the cruise OVIDE
Name of the network related to the platform MyOcean
Name of the network related to the platform GROUP
Name of the principal investigator Virginie THIERRY
Platform activity flag A
Positioning system ARGOS
Profiler CONDUCTIVITY ACCURACY 2
Profiler CRC TYPE 16
Profiler CYCLE PERIOD 10
Profiler CYCLE PERIOD 1 10
Profiler CYCLE PERIOD 2 10
Profiler EXPERIMENT ID OVIDE
Profiler IMMERSION DRIFT PERIOD 720
Profiler LAUNCH DATETIME 17/06/2010 15:59:00
Profiler LAUNCH LATITUDE 45.808
Profiler LAUNCH LONGITUDE -19.1032
Profiler PARKING DEPTH 1000
Profiler PROBE CODE 841
Profiler PROFILE DEPTH 2000
Profiler RECORDER CODE 60
Profiler REFERENCE DATETIME 18/06/2010 23:00:00
Profiler REFERENCE INTERNAL DATE 169
Profiler TYPE PROVOR
Profiler VERSION 4.41
Quality on launch date, time and location 1
Quality on start date 1
The accuracy of the sensor 8
The accuracy of the sensor 2.4
The accuracy of the sensor 0.002
The accuracy of the sensor 0.005
The deepest pressure sampled in the ascending profile 2000
The last valid station id of the platform 26124986
The name of the manufacturer Aanderaa
The name of the manufacturer Sea-Bird Electronics
The name of the manufacturer Sea-Bird Electronics
The name of the manufacturer NKE
The name of the manufacturer Druck
The number of times this cycle repeats 1
The pressure of subsurface drifts 1000
The program identifier used by the transmission system 02412
The repetition rate of transmission from the float 45
The resolution of the sensor 0.001
The resolution of the sensor 0.1
The resolution of the sensor 0.001
The resolution of the sensor 1
The serial number of the sensor None
The serial number of the sensor None
The serial number of the sensor None
The serial number of the sensor None
The telecommunications system used ARGOS
The total time of a cycle : descent + parking + ascent + surface 240
The units of accuracy and resolution of the sensor µM/L
The units of accuracy and resolution of the sensor Dbar
The units of accuracy and resolution of the sensor Degree Celsius
The units of accuracy and resolution of the sensor mS.cm-1
Transmission identifier (ARGOS, ORBCOMM, etc.) 44865
Type of sensor Optode 3830
Type of sensor SBE41CP
Type of sensor SBE41CP ¿ 2900 PSIA
Type of sensor SBE41CP
Version number of the data handbook 1.2