Description of all floats

Float 6900642

Code6900642
NamePROVOR Profiling Float
DescriptionCoriolis - OVIDE
Project OVIDE
InstitutionIFREMER
Data Assembly CenterIF : CORIOLIS
Status
First cycle date29/06/2008 15:51:45
Last cycle date14/05/2013 15:58:09
Float cycles178, 177, 176, 175, 174, 173, 172, 171, 170, 169, 168, 167, 166, 165, 164, 163, 162, 161, 160, 159, 158, 157, 156, 155, 154, 153, 152, 151, 150, 149, 148, 147, 146, 145, 144, 143, 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_6900642.png
Click here to access the interactive map
Waterfall profiles

Waterfall profiles (emphasis)

Overlayed profiles

Overlayed profiles (emphasis)

T/S Diagram
Section chart

Pressure chart
Battery voltage
Configuration
Calibration coefficients for this equationa1=0, a0=0.0000
Calibration equation for this parameterPSAL_ADJUSTED = a1 * PSAL + a0
Comment applying to this parameter calibrationDOXY=raw data transmitted by optode, Sref = 0
Comment applying to this parameter calibrationReal-time salinity adjustment
Data centre in charge of platform data processingIF
Date (UTC) of the first descent of the float.28/06/2008 23:00:00
Date of last update of the metadata of the platform28/09/2012 19:00:00
Date of last update of the trajectory of the platform21/05/2013 12:39:19
Date of the calibration20110117122315
Describe any anomalies or problems the float may have had.soft problem: O2 concentration is internally set to 0 when concentration measured by the sensor is greater than 327 muM/l
Direction of the profilesA
Identifier of the deployment platformThalassa
Instrument typeOIN-07-S3-DO-001
List of parameters with calibration informationPSAL
List of parameters with calibration informationDOXY
List of parameters with calibration informationTEMP
List of parameters with calibration informationPRES
List of parameters with calibration informationCNDC
List of parameters with real-time calibration informationPSAL
List of sensors on the floatTEMP
List of sensors on the floatPRES
List of sensors on the floatDOXY
List of sensors on the floatCNDC
Model of the floatPROVOR CTS3-DO
Name of the network related to the platformMyOcean
Name of the network related to the platformGROUP
Name of the principal investigatorVirginie THIERRY
PRES when the SBE pump is switched off5
Platform activity flagA
Positioning systemARGOS
Profiler CONDUCTIVITY ACCURACY2
Profiler CRC TYPE16
Profiler CYCLE PERIOD10
Profiler CYCLE PERIOD 110
Profiler CYCLE PERIOD 210
Profiler EXPERIMENT IDOVIDE
Profiler IMMERSION DRIFT PERIOD360
Profiler LAUNCH DATETIME27/06/2008 10:28:00
Profiler LAUNCH LATITUDE57.215
Profiler LAUNCH LONGITUDE-28.163
Profiler PARKING DEPTH1000
Profiler PROBE CODE841
Profiler PROFILE DEPTH2000
Profiler RECORDER CODE60
Profiler REFERENCE DATETIME28/06/2008 23:00:00
Profiler REFERENCE INTERNAL DATE180
Profiler TYPEPROVOR
Profiler VERSION4.4
Quality on launch date, time and location1
Quality on start date1
The deepest pressure sampled in the ascending profile2000
The last valid station id of the platform29440936
The name of the manufacturerMartec
The number of times this cycle repeats1
The pressure of subsurface drifts1000
The program identifier used by the transmission system02412
The repetition rate of transmission from the float40
The telecommunications system usedARGOS
The total time of a cycle : descent + parking + ascent + surface240
The type of battery packs in the floatLithium
The units of accuracy and resolution of the sensorDecibar
The units of accuracy and resolution of the sensormS/cm
The units of accuracy and resolution of the sensormicromole/kg
The units of accuracy and resolution of the sensordegree_Celsius
Transmission identifier (ARGOS, ORBCOMM, etc.)78678
Version number of the data handbook1.2
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 6900642 28/09/2012 19:00:00 0