Description of all floats

Float 6900642

Code 6900642
Name PROVOR Profiling Float
Description Coriolis - OVIDE
Project OVIDE
Institution IFREMER
Data Assembly Center IF : CORIOLIS
Status
First cycle date 29/06/2008 15:51:45
Last cycle date 19/05/2012 15:52:21
Float cycles 142, 141, 140, 139, 138, 137, 136, 135, 134, 133, 132, 131, 130, 129, 128, 127, 126, 125, 124, 123, 122, 121, 120, 119, 118, 117, 116, 115, 114, 113, 112, 111, 110, 109, 108, 107, 106, 105, 104, 103, 102, 101, 100, 99, 98, 97, 96, 95, 94, 93, 92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stations in Ascii, in Netcdf
Trajectory data in Ascii, in Netcdf
Graphics of individual profiles Verticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_6900642.png
Click here to access the interactive map
Waterfall profiles

Waterfall profiles (emphasis)

Overlayed profiles

Overlayed profiles (emphasis)

T/S Diagram
Section chart

Pressure chart
Battery voltage
Configuration
Calibration coefficients for this equation a1=0, a0=0.0000
Calibration equation for this parameter PSAL_ADJUSTED = a1 * PSAL + a0
Comment applying to this parameter calibration Real-time salinity adjustment
Comment applying to this parameter calibration DOXY=raw data transmitted by optode, Sref = 0
Data centre in charge of platform data processing IF
Date (UTC) of the first descent of the float. 28/06/2008 23:00:00
Date of last update of the metadatas of the platform 05/11/2009 19:00:00
Date of last update of the trajectory of the platform 24/05/2012 11:50:12
Date of the calibration 20110117122315
Describe any anomalies or problems the float may have had. soft problem: O2 concentration is internally set to 0 when concentration measured by the sensor is greater than 327 muM/l
Direction of the profiles A
Identifier of the deployment platform Thalassa
Instrument type PROVOR DO 07-DO-001
List of parameters with calibration information CNDC
List of parameters with calibration information DOXY
List of parameters with calibration information PRES
List of parameters with calibration information PSAL
List of parameters with calibration information TEMP
List of parameters with real-time calibration information PSAL
List of sensors on the float DOXY
List of sensors on the float PRES
List of sensors on the float TEMP
List of sensors on the float CNDC
Model of the float PROVOR CTS3 DO
Name of the network related to the platform MyOcean
Name of the network related to the platform GROUP
Name of the network related to the platform GROUP
Name of the principal investigator Virginie THIERRY
Platform activity flag A
Positioning system ARGOS
Profiler CONDUCTIVITY ACCURACY 2
Profiler CRC TYPE 16
Profiler CYCLE PERIOD 10
Profiler CYCLE PERIOD 1 10
Profiler CYCLE PERIOD 2 10
Profiler EXPERIMENT ID OVIDE
Profiler IMMERSION DRIFT PERIOD 360
Profiler LAUNCH DATETIME 27/06/2008 10:28:00
Profiler LAUNCH LATITUDE 57.215
Profiler LAUNCH LONGITUDE -28.163
Profiler PARKING DEPTH 1000
Profiler PROBE CODE 841
Profiler PROFILE DEPTH 2000
Profiler RECORDER CODE 60
Profiler REFERENCE DATETIME 28/06/2008 23:00:00
Profiler REFERENCE INTERNAL DATE 180
Profiler TYPE PROVOR
Profiler VERSION 4.4
Quality on launch date, time and location 1
Quality on start date 1
The deepest pressure sampled in the ascending profile 2000
The last valid station id of the platform 26124966
The name of the manufacturer Martec
The number of times this cycle repeats 1
The pressure of subsurface drifts 1000
The program identifier used by the transmission system 02412
The repetition rate of transmission from the float 40
The telecommunications system used ARGOS
The total time of a cycle : descent + parking + ascent + surface 240
The units of accuracy and resolution of the sensor Decibar
The units of accuracy and resolution of the sensor degree_Celsius
The units of accuracy and resolution of the sensor micromole/kg
The units of accuracy and resolution of the sensor mS/cm
Transmission identifier (ARGOS, ORBCOMM, etc.) 78678
Version number of the data handbook 1.2