| Bathy | 2500 |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Data centre in charge of platform data processing | IF |
| Date (UTC) of the first descent of the float. | 02/08/2012 08:00:00 |
| Date of last update of the metadata of the platform | 01/10/2012 19:00:00 |
| Direction of the profiles | A |
| Identifier of the deployment platform | Hurricane |
| Identifier of the mission used to deploy the float | SOCIB ICTS |
| Instrument type | APEX 6259 - 8373 |
| List of parameters with calibration information | PRES |
| List of parameters with calibration information | PSAL |
| List of parameters with calibration information | TEMP |
| List of parameters with calibration information | CNDC |
| List of sensors on the float | PRES |
| List of sensors on the float | TEMP |
| List of sensors on the float | CNDC |
| Model of the float | APEX-SBE-APF9I |
| Name of the cruise | Hurricane0712 |
| Name of the principal investigator | VELEZ BELCHI Pedro |
| Platform activity flag | A |
| Positioning system | GPS |
| Profiler CONDUCTIVITY ACCURACY | 2 |
| Profiler CRC TYPE | 16 |
| Profiler CYCLE PERIOD | 5 |
| Profiler CYCLE PERIOD 1 | 50 |
| Profiler EXPERIMENT ID | ARGOMED |
| Profiler EXPERIMENT ID | ARGO SPAIN |
| Profiler IMMERSION DRIFT PERIOD | 9999 |
| Profiler LAUNCH DATETIME | 02/08/2012 08:00:00 |
| Profiler LAUNCH LATITUDE | 39.7757 |
| Profiler LAUNCH LONGITUDE | 2.083 |
| Profiler PARKING DEPTH | 700 |
| Profiler PROBE CODE | 846 |
| Profiler PROFILE DEPTH | 2000 |
| Profiler RECORDER CODE | 60 |
| Profiler REFERENCE DATETIME | 02/08/2012 08:00:00 |
| Profiler REFERENCE INTERNAL DATE | 9999 |
| Profiler TYPE | APEX |
| Profiler VERSION | 012811 |
| Quality on launch date, time and location | 1 |
| Quality on start date | 1 |
| The deepest pressure sampled in the ascending profile | 2000 |
| The last valid station id of the platform | 29472019 |
| The name of the manufacturer | SBE |
| The name of the manufacturer | TELEDYNE Webb Research |
| The name of the manufacturer | SBE |
| The name of the manufacturer | SBE |
| The number of times this cycle repeats | 1 |
| The pressure of subsurface drifts | 700 |
| The serial number of the sensor | 4121 |
| The serial number of the sensor | 4121 |
| The serial number of the sensor | 4121 |
| The telecommunications system used | IRIDIUM |
| The total time of a cycle : descent + parking + ascent + surface | 120 |
| The type of battery packs in the float | Alkaline |
| The units of accuracy and resolution of the sensor | mS.cm-1 |
| The units of accuracy and resolution of the sensor | Degree Celsius |
| The units of accuracy and resolution of the sensor | Dbar |
| Transmission identifier (ARGOS, ORBCOMM, etc.) | 8373 |
| Type of sensor | 41 |
| Type of sensor | 41 |
| Type of sensor | 41 |
| Version number of the data handbook | 1.2 |