Description of all floats

Float 6900978

Code6900978
NameARVOR Profiling Float
DescriptionARGO ITALY
Project ARGOMED ARGO_ITALY
InstitutionOGS, ISTITUTO NAZIONALE DI OCEANOGRAFIA E GEOFISICA SPERMENTALE
Data Assembly CenterIF : CORIOLIS
Status
First cycle date18/03/2012 06:00:00
Last cycle date16/06/2013 07:04:55
Float cycles92, 91, 90, 89, 88, 87, 86, 85, 84, 83, 82, 81, 80, 79, 78, 77, 76, 75, 74, 73, 72, 71, 70, 69, 68, 67, 66, 65, 64, 63, 62, 61, 60, 59, 58, 57, 56, 55, 54, 53, 52, 51, 50, 49, 48, 47, 46, 45, 44, 43, 42, 41, 40, 39, 38, 37, 36, 35, 34, 33, 32, 31, 30, 29, 28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_6900978.png
Click here to access the interactive map
Waterfall profiles
Waterfall profiles (emphasis)
Overlayed profiles
Overlayed profiles (emphasis)
T/S Diagram
Section chart
Pressure chart
Battery voltage
Configuration
Bathy3517
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Data centre in charge of platform data processingIF
Date (UTC) of the first descent of the float.16/03/2012 10:45:00
Date of last update of the metadata of the platform28/09/2012 19:00:00
Date of last update of the trajectory of the platform16/06/2013 09:20:44
Direction of the profilesB
Firmware version5605A06
Identifier of stations used to verify the first profileYES, XBT not available yet
Identifier of the deployment platformPOURQUOI PAS?
Instrument typeOIN-11-IT-AR-L-001
List of parameters with calibration informationTEMP
List of parameters with calibration informationPRES
List of parameters with calibration informationPSAL
List of parameters with calibration informationCNDC
List of sensors on the floatCNDC
List of sensors on the floatPRES
List of sensors on the floatTEMP
Model of the floatARVOR-L
Name of the cruiseMOCOSED
Name of the principal investigatorPierre Marie POULAIN
PRES when the SBE pump is switched off5
Platform activity flagA
Positioning systemARGOS
Profiler CONDUCTIVITY ACCURACY2
Profiler CRC TYPE16
Profiler CYCLE PERIOD5
Profiler CYCLE PERIOD 15
Profiler CYCLE PERIOD 25
Profiler EXPERIMENT IDARGOMED
Profiler EXPERIMENT IDARGO_ITALY
Profiler IMMERSION DRIFT PERIOD720
Profiler LAUNCH DATETIME16/03/2012 11:41:00
Profiler LAUNCH LATITUDE39.4004
Profiler LAUNCH LONGITUDE14.0076
Profiler PARKING DEPTH350
Profiler PROBE CODE844
Profiler PROFILE DEPTH700
Profiler RECORDER CODE60
Profiler REFERENCE DATETIME18/03/2012 06:00:00
Profiler REFERENCE INTERNAL DATE78
Profiler TYPEPROVOR
Profiler VERSION4.51
Quality on launch date, time and location1
Quality on start date1
The accuracy of the sensor2.4
The accuracy of the sensor0.005
The accuracy of the sensor0.002
The deepest pressure sampled in the ascending profile700
The deepest pressure sampled in the ascending profile2000
The last valid station id of the platform29712421
The name of the manufacturerSea-Bird Electronics
The name of the manufacturerSea-Bird Electronics
The name of the manufacturerDruck
The name of the manufacturerNKE
The number of times this cycle repeats1
The pressure of subsurface drifts350
The pressure of subsurface drifts350
The program identifier used by the transmission system2765
The repetition rate of transmission from the float40
The resolution of the sensor0.001
The resolution of the sensor0.1
The resolution of the sensor0.001
The serial number of the sensor4001
The serial number of the sensorXXXX
The serial number of the sensor4001
The telecommunications system usedARGOS
The total time of a cycle : descent + parking + ascent + surface120
The total time of a cycle : descent + parking + ascent + surface120
The type of battery packs in the floatLithium
The units of accuracy and resolution of the sensormS.cm-1
The units of accuracy and resolution of the sensorDegree Celsius
The units of accuracy and resolution of the sensorDbar
Transmission identifier (ARGOS, ORBCOMM, etc.)114255
Type of sensorSBE41CP
Type of sensorSBE41CP ¿ 2900 PSIA
Type of sensorSBE41CP
Version number of the data handbook1.2
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 6900978 28/09/2012 19:00:00 0