Description of all floats

Float 6901028

Code6901028
NamePROVOR Profiling Float
DescriptionCORIOLIS
Project CORIOLIS
InstitutionIFREMER
Data Assembly CenterIF : CORIOLIS
Status
First cycle date15/07/2012 23:00:00
Last cycle date22/04/2013 09:21:18
Float cycles28, 27, 26, 25, 24, 23, 22, 21, 20, 19, 18, 17, 16, 15, 14, 13, 12, 11, 10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0
Stationsin Ascii, in Netcdf
Trajectory datain Ascii, in Netcdf
Graphics of individual profilesVerticals profiles, Immersion profiles
Map
http://www.ifremer.fr/co/co0533/cdcFloat_6901028.png
Click here to access the interactive map
Waterfall profiles

Waterfall profiles (emphasis)

Overlayed profiles

Overlayed profiles (emphasis)

T/S Diagram
Section chart

Pressure chart
Battery voltage
Configuration
Anderaa calibration coeff 0.003147
Anderaa calibration coeff 0.00013802
Anderaa calibration coeff 2.3962e-006
Anderaa calibration coeff 4.1591
Anderaa calibration coeff -0.29017
Anderaa calibration coeff -48.159
Anderaa calibration coeff 215.94
Bathy2277
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration coefficients for this equationNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Calibration equation for this parameterNone
Data centre in charge of platform data processingIF
Date (UTC) of the first descent of the float.14/07/2012 01:28:00
Date of last update of the metadata of the platform28/09/2012 19:00:00
Date of last update of the trajectory of the platform29/04/2013 01:42:11
Delay Before Mission0
Depth Slice Thickness25
Depth intermediate threshold500
Direction of the profilesB
Firmware version5817A05
INTERMEDIATE SURFACE THRESHOLD10
Identifier of stations used to verify the first profileyes, CTD not available yet
Identifier of the deployment platformSARMIETO DE GAMBOA
Instrument typeOIN-11-S3-DO-008
Intermediate Slice Thickness10
List of parameters with calibration informationTEMP
List of parameters with calibration informationDOXY
List of parameters with calibration informationPRES
List of parameters with calibration informationPSAL
List of parameters with calibration informationCNDC
List of sensors on the floatCNDC
List of sensors on the floatDOXY
List of sensors on the floatPRES
List of sensors on the floatTEMP
Meteorologymer belle
Model of the floatPROVOR CTS3-DO
Name of the cruisecatarina
Name of the principal investigatorVirginie THIERRY
PRES when the SBE pump is switched off2
Period Ascent Profile10
Period Descent Profile0
Platform activity flagI
Positioning systemARGOS
Profiler CONDUCTIVITY ACCURACY2
Profiler CRC TYPE16
Profiler CYCLE PERIOD10
Profiler CYCLE PERIOD 110
Profiler CYCLE PERIOD 210
Profiler EXPERIMENT IDCORIOLIS
Profiler IMMERSION DRIFT PERIOD720
Profiler LAUNCH DATETIME14/07/2012 02:02:00
Profiler LAUNCH LATITUDE59.1015
Profiler LAUNCH LONGITUDE -33.822
Profiler PARKING DEPTH1000
Profiler PROBE CODE841
Profiler PROFILE DEPTH2000
Profiler RECORDER CODE60
Profiler REFERENCE DATETIME15/07/2012 23:00:00
Profiler REFERENCE INTERNAL DATE197
Profiler TYPEPROVOR
Profiler VERSION4.42
Quality on launch date, time and location1
Quality on start date1
Surface Slice Thickness1
The accuracy of the sensor2.4
The accuracy of the sensor8
The accuracy of the sensor0.005
The accuracy of the sensor0.002
The deepest pressure sampled in the ascending profile2000
The last valid station id of the platform29261449
The name of the manufacturerAanderaa
The name of the manufacturerSea-Bird Electronics
The name of the manufacturerSea-Bird Electronics
The name of the manufacturerNKE
The name of the manufacturerDruck
The number of times this cycle repeats1
The pressure of subsurface drifts1000
The program identifier used by the transmission system2412
The repetition rate of transmission from the float40
The resolution of the sensor1
The resolution of the sensor0.001
The resolution of the sensor0.001
The resolution of the sensor0.1
The serial number of the sensorXXXX
The serial number of the sensorA9539
The serial number of the sensorA9539
The serial number of the sensor711
The telecommunications system usedARGOS
The total time of a cycle : descent + parking + ascent + surface240
The type of battery packs in the floatLithium
The units of accuracy and resolution of the sensorDbar
The units of accuracy and resolution of the sensorDegree Celsius
The units of accuracy and resolution of the sensoru M/l
The units of accuracy and resolution of the sensormS.cm-1
Transmission identifier (ARGOS, ORBCOMM, etc.)117943
Type of sensorOptode 4330
Type of sensorSBE41CP
Type of sensorSBE41CP
Type of sensorSBE41CP ¿ 2900 PSIA
Version number of the data handbook1.2
Missing measures percentages chart_missing_measures_ratios
Missing cycles chart_missing_cycles
Technical alerts chart_tech_alert
Technical parameters 6901028 28/09/2012 19:00:00 0