| Bathy | 28 |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration coefficients for this equation | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Calibration equation for this parameter | None |
| Data centre in charge of platform data processing | IF |
| Date (UTC) of the first descent of the float. | 02/10/2012 14:30:00 |
| Date of last update of the trajectory of the platform | 24/01/2013 03:17:09 |
| Direction of the profiles | B |
| Identifier of the deployment platform | EUROPE |
| Instrument type | OIN-12-ARC-001 |
| List of parameters with calibration information | CNDC |
| List of parameters with calibration information | PRES |
| List of parameters with calibration information | PSAL |
| List of parameters with calibration information | TEMP |
| List of sensors on the float | TEMP |
| List of sensors on the float | PRES |
| List of sensors on the float | CNDC |
| Model of the float | ARVOR IRIDIUM cotier |
| Name of the cruise | RHOMA-AUV2012 |
| Name of the principal investigator | Xavier ANDRE |
| PRES when the SBE pump is switched off | 5 |
| Platform activity flag | I |
| Positioning system | GPS |
| Profiler EXPERIMENT ID | CORIOLIS |
| Profiler LAUNCH DATETIME | 02/10/2012 14:44:00 |
| Profiler LAUNCH LATITUDE | 43.3146 |
| Profiler LAUNCH LONGITUDE | 4.8273 |
| Profiler PROBE CODE | 844 |
| Profiler RECORDER CODE | 64 |
| Profiler REFERENCE DATETIME | 02/10/2012 00:00:00 |
| Profiler TYPE | PROVOR |
| Profiler VERSION | 5.3 |
| Quality on launch date, time and location | 1 |
| Quality on start date | 1 |
| The accuracy of the sensor | 3 |
| The accuracy of the sensor | 0.03 |
| The accuracy of the sensor | 0.03 |
| The last valid station id of the platform | 28083381 |
| The name of the manufacturer | NKE |
| The name of the manufacturer | Sea-Bird Electronics |
| The name of the manufacturer | Sea-Bird Electronics |
| The name of the manufacturer | Sea-Bird Electronics |
| The program identifier used by the transmission system | n/a |
| The resolution of the sensor | 0.1 |
| The resolution of the sensor | 0.001 |
| The serial number of the sensor | None |
| The serial number of the sensor | None |
| The serial number of the sensor | None |
| The telecommunications system used | IRIDIUM |
| The type of battery packs in the float | Lithium |
| The units of accuracy and resolution of the sensor | Degree Celsius |
| The units of accuracy and resolution of the sensor | Dbar |
| The units of accuracy and resolution of the sensor | mS.cm-1 |
| Transmission identifier (ARGOS, ORBCOMM, etc.) | 300234011881050 |
| Type of sensor | SBE41CP |
| Type of sensor | SBE41CP |
| Type of sensor | SBE41CP |
| Version number of the data handbook | 1.2 |